CCYLS - 5240 FLUX REMOVER

  • MSDS: CCYLS
  • Manufacturer: KESTER SOLDER
  • Product Name: 5240 FLUX REMOVER
  • National Stock Number: 3439-00N076009
Product Identification

Product ID:5240 FLUX REMOVER
MSDS Date:03/12/1996
FSC:3439
NIIN:00N076009
MSDS Number: CCYLS

Responsible Party
KESTER SOLDER
515 E TOUHY AVE
DES PLAINES, IL 60018
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 708-297-1600

Preparer: M. WISE

Cage: GO345

Contractor
KESTER SOLDER
2588 DES PLAINES, IL 60018-2675 US

Telephone: 708-297-1600

Cage: GO345

Ingredients

ETHYLENE, TETRACHLORO-; (TETRACHLOROETHYLENE) (SARA 313)

CAS: 127-18-4

RTECS: KX3850000

Fraction By Weight: 91%

OSHA PEL 100 PPM

ACGIH TLV: 25 PPM; 100 STEL

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


ACETIC ACID, BUTYL ESTER; (BUTYL ACETATE) (CERCLA)

CAS: 123-86-4

RTECS: AF7350000

Fraction By Weight: 6%

OSHA PEL 150 PPM

ACGIH TLV: 150 PPM; 200 STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


INHIBITORS

Fraction By Weight: 2%

OSHA PEL N/K

ACGIH TLV: N/K


RPTD/PRLNGD CONTACT W/SKIN CAN CAUSE DEFATTING &

RTECS: 9999999ZZ


DERMATITIS. SEVERE, ACUTE EXPOSURE HAS BEEN

RTECS: 9999999ZZ


FAILURE. CHRONIC EXPOSURE MAY DAMAGE LIVER &

RTECS: 9999999ZZ


TEMPERATURES EXCEEDING 90F(32C). AVOID

RTECS: 9999999ZZ


CONTAINERS CAUTIOUSLY TO ALLOW VENTING OF INTERNAL

RTECS: 9999999ZZ


& FULL LENGTH FACESHIELD .

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:CHLOROCARBON MATLS HAVE PRDCED SENSIT
OF THE MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & COULD HAVE A
SIMILAR EFFECT IN HUMANS. ADRENOMIMETICS (EG, EPINEPHRINE) MAY BE
CONTRA-INDICATED EXCEPT FOR LIFE- SUSTAINING USES IN HUMANS
ACUTELY/CHRONICALLY EXPOSED TO CHLOROCARBONS . INHAL: DIZZINESS,
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:TETRACHLOROETHYLENE: IARC MONOGRAPHS ON
THE EVALUATION OF CARCINOGENIC RISK OF CHEMICALS TO MAN, VOL 63, PG
159,(SUPDAT)
Effects of Overexposure:HLTH HAZ: NARCOTIC EFFECT IN HIGH CONCS. ACTS
AS A LOCAL IRRITANT TO EYES, NOSE & RESPIRATORY TRACT. SKIN
CONTACT: LIQUID IS SLIGHT TO MODERATE IRRITANT TO SKIN. EYES:
LIQUID IS MODERATE TO SEVERE IRR ITANT TO EYES. VAPORS MAY ALSO
CAUSE IRRITATION. INGEST: LIQUID IS MODERATELY TOXIC & MAY BE
HARMFUL IF (SUPDAT)
Medical Cond Aggravated by Exposure:SEVERE, ACUTE EXPOSURE HAS BEEN
ATTRIBUTED TO VENTRICULAR FIBRILLATION RESULTING IN CARDIAC
FAILURE. CHRONIC EXPOSURE MAY DAMAGE LIVER AND KIDNEYS.

First Aid

First Aid:SEEK MEDICAL ASSISTANCE FOR FURTHER TREATMENT, OBSERVATION &
SUPPORT IF NEEDED. EYES: FLUSH WITH PLENTY OF WATER & GET MEDICAL
ATTENTION. SKIN: WASH WITH SOAP & WATER. REPLACE MOISTURE WITH HAND
LOTIO N. INHAL: REMOVE VICTIM TO FRESH AIR. PROVIDE OXYGEN IF
BREATHING IS DIFFICULT. INGEST: INDUCE VOMITING. KEEP VICTIM'S HEAD
BELOW HIPS TO PREVENT ASPIRATION INTO LUNGS. GET MEDICAL ATTENTION.

Fire Fighting

Flash Point Method:TOC
Flash Point:NONE
Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH APPROVED PRESSURE DEMAND SCBA AND
FULL PROTECTIVE EQUIPMENT . USE WATERSPRAY TO COOL FIRE-EXPOSED
CONTAINERS AND CONTROL VAPORS.
Unusual Fire/Explosion Hazard:SEALED CNTNRS COULD EXPLODE DURING FIRE
RESULTING IN HIGHLY TOXIC FUMES. HAZ COMBUST PRODS: CARBON
MONOXIDE, CARBON DIOXIDE, HYDROCHLORIC ACID & PHOSGENE GAS.

Accidental Release

Spill Release Procedures:CONTAIN SPILL TO SMALLEST POSSIBLE AREA.
ABSORB WITH CLAY, DIATOMACEIOUS EARTH OR OTHER INERT MATERIALS AND
DISPOSE. AVOID BREATHING VAPORS. REMOVE SOAKED CLOTHING.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT USE A CUTTING TORCH ON
CONTAINERS (EVEN EMPTY) AS RESIDUAL MAY EXPLODE. KEEP CONTAINER
SEALED WHEN NOT IN USE. DO NOT STORE AT (ING 8)
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN THE GENERAL
VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT AND/OR
UV RADIATION MAY CAUSE THE FORMATION OF HCL AND/OR PHOSGENE .

Exposure Controls

Respiratory Protection:NIOSH APPROVED RESPIRATORY PROTECTION AS
REQUIRED TO MEET TLV REQUIREMENTS. FOR HIGHER CONCENTRATIONS USE
NIOSH APPROVED ORGANIC CARTRIDGE RESPIRATORY OR NIOSH APPROVED
SELF-CONTAINED BREATHING APPARA TUS.
Ventilation:PROVIDE ADEQUATE EXHAUST VENTILATION (GENERAL AND/OR LOCAL)
TO MEET TLV REQUIREMENTS.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS (ING 10)
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
IMPERMEABLE APRON WHEN SPLASHING IS LIKELY TO OCCUR.
Work Hygienic Practices:AVOID BREATHING VAPORS. AVOID SKIN AND EYE
CONTACT.
Supplemental Safety and Health
EXPLAN OF CARCIN: 1995:GROUP 2A. NTP 7TH ANNUAL REPORT ON CARCINOGENS,
1994:ANTICIPATED TO BE CARCINOGEN. ANIMAL:LIVER TUMORS. EFTS OF
OVEREXP: SWALLOWED. MAY CAUSE CNS DEPRESSION, VOMITING & IRRITATI
ON TO UPPER DIGESTIVE TRACT. CNS DEPRESSION MAY BE EVIDENCED BY
GIDDINESS, HEADACHE, DIZZINESS & NAUSEA. (ING 5)

Chemical Properties

Boiling Pt:B.P. Text:294F,146C
Vapor Pres:13.6 @ 20C
Vapor Density:5.0
Spec Gravity:1.57 (H*2O=1)
Evaporation Rate & Reference:1.8 (BUTYL ACETATE=1)
Solubility in Water:0% BY WEIGHT
Appearance and Odor:COLORLESS LIQUID WITH CHARACTERISTIC ODOR.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, ALKALINE FUMES OR ALKALI METALS.
Stability Condition to Avoid:NOT APPLICABLE.
Hazardous Decomposition Products:MAY DECOMPOSE IN CONTACT WITH FLAMES
TO FORM PHOSGENE GAS AND HYDROCHLORIC ACID.

Disposal

Waste Disposal Methods:ACCORDING TO LOCAL, STATE AND FEDERAL
REGULATIONS; USUALLY BY INCINERATION. CAUTION: EMPTY CONTAINERS MAY
CONTAIN PRODUCT RESIDUE. OBSERVE ALL LABEL PRECAUTIONS.

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.